Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 209
Filtrar
2.
J Arrhythm ; 40(2): 382-384, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38586852

RESUMO

Background: The impact of chronic kidney disease (CKD) on atrial fibrillation outcomes (AF) is not well understood. Methods: We conducted analyses of comorbid AF and CKD related death in the United States from 1999 to 2020 using descriptive epidemiology. Results: Age-adjusted mortality rates (AAMR) per 100,000 increased from 0.39 in 1999 to 1.65 in 2020. Non-Hispanic populations (1.01) and nonmetropolitan areas (1.08) had higher AAMRs compared to Hispanic (0.62) and metropolitan (0.97) areas. Midwestern (1.11) and Western (1.13) US regions recorded the highest AAMRs. Conclusions: These findings highlight the need for interventions to address AF death disparities in patients with CKD.

3.
JACC Clin Electrophysiol ; 10(4): 709-715, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38310489

RESUMO

BACKGROUND: High-voltage pulses can cause hemolysis. OBJECTIVES: The authors evaluated the occurrence of hemoglobinuria after pulsed-field ablation (PFA) and its impact on renal function in patients with atrial fibrillation (AF). METHODS: A consecutive series of patients with AF undergoing PFA were included in this analysis. The initial patients who did not receive postablation hydration immediately after the procedure were classified as group 1 (n = 28), and the rest of the study patients who received planned fluid infusion (0.9% sodium chloride ≥2 L) after the procedure were categorized as group 2 (n = 75). RESULTS: Of the 28 patients in group 1, 21 (75%) experienced hemoglobinuria during the 24 hours after catheter ablation. The mean postablation serum creatinine (S-Cr) was significantly higher than the baseline value in those 21 patients (1.46 ± 0.28 mg/dL vs 0.86 ± 0.24 mg/dL, P < 0.001). Of those 21 patients, 4 (19%) had S-Cr. >2.5 mg/dL (mean: 2.95 ± 0.21 mg/dL). The mean number of PF applications was significantly higher in those 4 patients than in the other 17 patients experiencing hemoglobinuria (94.63 ± 3.20 vs 46.75 ± 9.10, P < 0.001). In group 2 patients, no significant changes in S-Cr were noted. The group 2 patients received significantly higher amounts of fluid infusion after catheter ablation than did those in group 1 (2,082.50 ± 258.08 mL vs 494.01 ± 71.65 mL, P < 0.001). In multivariable analysis, both hydration (R2 = 0.63, P < 0.01) and number of PFA applications (R2 = 0.33, P < 0.01) were independent predictors of postprocedure acute kidney injury. CONCLUSIONS: On the basis of our findings, both the number of PFA applications and postablation hydration were independent predictors of renal insult that could be prevented using planned fluid infusion immediately after the procedure.


Assuntos
Injúria Renal Aguda , Fibrilação Atrial , Ablação por Cateter , Hemoglobinúria , Humanos , Fibrilação Atrial/cirurgia , Masculino , Feminino , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Pessoa de Meia-Idade , Injúria Renal Aguda/prevenção & controle , Injúria Renal Aguda/etiologia , Idoso , Hemoglobinúria/etiologia , Hemoglobinúria/prevenção & controle , Creatinina/sangue , Estudos Retrospectivos , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Hidratação/métodos
4.
Heart Rhythm ; 2024 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-38246567

RESUMO

BACKGROUND: Long-term oral anticoagulation is the mainstay therapy for thromboembolic (TE) prevention in patients with atrial fibrillation. However, left atrial appendage occlusion (LAAO) could be a safe alternative to direct oral anticoagulants (DOACs) in patients with a very high TE risk profile. OBJECTIVE: The purpose of this study was to compare the safety and efficacy of LAAO vs DOACs in patients with atrial fibrillation at very high stroke risk (CHA2DS2-VASc [congestive heart failure, hypertension, age ≥ 75 years, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age 65-74 years, sex category] score ≥ 5). METHODS: Data from patients with CHA2DS2-VASc score ≥ 5 were extracted from a prospective multicenter database. To attenuate the imbalance in covariates between groups, propensity score matching was used (covariates: CHA2DS2-VASc and HAS-BLED [hypertension, abnormal renal or liver function, stroke, bleeding, labile international normalized ratio, elderly, drugs or alcohol] scores), which resulted in a matched population of 277 patients per group. The primary end point was a composite of cardiovascular death, TE events, and clinically relevant bleeding during follow-up. RESULTS: Of 2381 patients, 554 very high risk patients were included in the study (mean age 79 ± 7 years; CHA2DS2-VASc score 5.8 ± 0.9; HAS-BLED score 3.0 ± 0.9). The mean follow-up duration was 25 ± 11 months. A higher incidence of the composite end point was documented with DOACs compared with LAAO (14.9 events per 100 patient-years in the DOAC group vs 9.4 events per 100 patient-years in the LAAO group; P = .03). The annualized clinically relevant bleeding risk was higher with DOACs (6.3% vs 3.2%; P = .04), while the risk of TE events was not different between groups (4.1% vs 3.2%; P = .63). CONCLUSION: In high-risk patients, LAAO had a similar stroke prevention efficacy but a significantly lower risk of clinically relevant bleeding when compared with DOACs. The clinical benefit of LAAO became significant after 18 months of follow-up.

5.
JACC Clin Electrophysiol ; 10(1): 31-39, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37943190

RESUMO

BACKGROUND: Bilateral cardiac sympathetic denervation (BCSD) for refractory life-threatening ventricular arrhythmias is a neuromodulatory intervention targeting sympathetically driven focal or re-entrant ventricular arrhythmias. OBJECTIVES: This study sought to provide a more complete and successful option for intervention in patients in whom premature ventricular contraction (PVC) ablation is not feasible or has been unsuccessful. METHODS: A total of 43 patients with >5% PVC burden and concomitant nonischemic cardiomyopathy (NICM) who previously failed medical and ablation therapies were referred for BCSD. All patients underwent bilateral video-assisted thoracoscopic surgical approach with T1-T4 sympathectomy. Primary effectiveness endpoints were postprocedural PVC burden resolution, improvement in left ventricular ejection fraction (LVEF), and cessation of antiarrhythmic drugs (AADs). Safety endpoints included peri- and postprocedural complications. Outcomes were assessed over a 1-year follow-up period. RESULTS: Among the 43 patients who underwent BCSD, the mean age was 52.3 ± 14.7 years, 69.8% of whom were male patients. Presenting mean LVEF was 38.7% ± 7.8%, and PVC burden was 23.7% ± 9.9%. There were significant reductions in PVC burden postprocedurally (1.3% ± 1.1% post-BCSD, compared with 23.7% ± 9.9% pre-BCSD, P < 0.001) and improvements in LVEF (46.3% ± 9.5% post-BCSD, compared with 38.7% ± 7.8% pre-BCSD, P < 0.001). The rate of ICD therapies decreased from 81.4% (n = 35) to 11.6% (n = 5) (P < 0.001), leading to a significant reduction in use of AADs (100.0% to 11.6%, P < 0.001) and improvement in mean NYHA functional class (2.5 ± 0.5 to 1.4 ± 0.2, P < 0.001). Major intraoperative complications were seen in 4.7% of patients (hemothorax and chylothorax). Of the patients, 81.4% (n = 35) experienced no mortality or major complications over a 1-year follow-up period, with the remaining still within their first year postprocedure. CONCLUSIONS: BCSD is effective for the management of refractory PVCs and ventricular tachycardia who have failed previous ablation therapy.


Assuntos
Cardiomiopatias , Complexos Ventriculares Prematuros , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Volume Sistólico , Função Ventricular Esquerda , Antiarrítmicos/uso terapêutico , Simpatectomia/efeitos adversos , Simpatectomia/métodos
6.
JACC Clin Electrophysiol ; 10(1): 68-78, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37897465

RESUMO

BACKGROUND: Injury to the esophagus has been reported in a high percentage of patients undergoing ablation of atrial fibrillation (AF). OBJECTIVES: This study assessed the incidence of esophageal injury in patients undergoing ablation of AF with and without an esophageal deviating device. METHODS: This prospective, randomized, multicenter, double-blinded, controlled Food and Drug Administration investigational device exemption trial compared the incidence of ablation-related esophageal lesions, as assessed by endoscopy, in patients undergoing AF ablation assigned to a control group (luminal esophageal temperature [LET] monitoring alone) compared with patients randomized to a deviation group (esophagus deviation device + LET). This novel deviating device uses vacuum suction and mechanical deflection to deviate a segment of the esophagus, including the trailing edge. RESULTS: The data safety and monitoring board recommended stopping the study early after randomizing 120 patients due to deviating device efficacy. The primary study endpoint, ablation injury to the esophageal mucosa, was significantly less in the deviation group (5.7%) in comparison to the control group (35.4%; P < 0.0001). Control patients had a significantly higher severity and greater number of ablation lesions per patient. There was no adverse event assigned to the device. By multivariable analysis, the only feature associated with reduced esophageal lesions was randomization to deviating device (OR: 0.13; 95% CI: 0.04-0.46; P = 0.001). Among control subjects, there was no difference in esophageal lesions with high power/short duration (31.8%) vs other radiofrequency techniques (37.2%; P = 0.79). CONCLUSIONS: The use of an esophageal deviating device resulted in a significant reduction in ablation-related esophageal lesions without any adverse events.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Ablação por Radiofrequência , Humanos , Estudos Prospectivos , Ablação por Cateter/métodos , Esôfago/cirurgia
7.
J Cardiovasc Electrophysiol ; 35(1): 16-24, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37890041

RESUMO

INTRODUCTION: Mechanical force to achieve transseptal puncture (TSP) using a standard needle may lead to overshooting and injury, and can potentially be avoided using a radiofrequency (RF)-powered needle or wire. Applying electrocautery to needles and guidewires as an alternative to purpose-built RF systems has been associated with safety risks, such as tissue coring and thermal damage. The commercially available AcQCross needle-dilator system (Medtronic) features a sharp open-ended needle for mechanical puncture, as well as a built-in connector to enable energy delivery for RF puncture. This investigation compares the safety and efficacy of the AcQCross needle to the dedicated VersaCross RF wire system and generator (Baylis Medical/Boston Scientific). METHODS: In an ex vivo porcine model, VersaCross wire punctures were performed using 1 s, constant mode (approx. 10 W) with maximum two attempts. AcQCross punctures were performed by applying energy for 2 s using a standard electrosurgical generator at 10 W (max. five attempts), 20 W (max. two attempts), and 30 W (max. two attempts). Efficacy was assessed in terms of puncture success and a number of energy applications required for TSP. Safety was assessed quantitatively as force required for TSP, energy required to puncture, and incidence of tissue coring, as well as by qualitative assessment of puncture sites. Additional qualitative observation of tissue cores and debris were obtained from TSP performed in live swine. RESULTS: RF TSP was 100% successful using the VersaCross wire with 1.0 ± 0.0 attempts. When power was used with the AcQCross needle, it failed to puncture at low (10 and 20 W) power settings; TSP was achieved with 30 W of energy with 91% success using 1.53 ± 0.51 attempts (p < .05 vs. VC) with greater variability (F1,33 = 9223.5, p < .0001). Compared to RF puncture using the VersaCross system, mechanical puncture, alone, using the AcQcross needle required six times more force (8 mm additional forward device displacement) to perforate the septum. Qualitative assessment of puncture sites revealed larger defects and more tissue charring with the AcQCross needle at 30 W compared to punctures with VersaCross wire. Tissue coring with the open-ended AcQCross needle was observed in vivo and measured to occur in 57% of punctures using the ex vivo model; no coring was observed with the closed-tip VersaCross wire. CONCLUSIONS: The AcQCross needle frequently required higher energy of 30 W to achieve RF TSP and was associated with tissue coring and charring, which have been, previously, reported when electrifying a standard open-ended mechanical needle or guidewire. These findings may limit safety and effectiveness compared to the VersaCross system.


Assuntos
Ablação por Cateter , Suínos , Animais , Desenho de Equipamento , Eletrocoagulação , Agulhas , Punções , Modelos Animais , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 35(2): 278-287, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38073051

RESUMO

INTRODUCTION: Transvenous lead extraction (TLE), while mostly a safe procedure, has risk of serious periprocedural complications. As such, overnight hospitalization remains a routine practice. In our center, we routinely discharge patients on the same day following an uncomplicated TLE. METHODS: This is a retrospective study of 265 consecutive patients who underwent uncomplicated TLE in our center between 2019 and 2021. Same-day discharge (SDD) patients are compared with those who stayed at least overnight for observation after the TLE procedure (non-SDD group). To assess the safety of an SDD strategy after uncomplicated TLE, the main study endpoint was to compare the rate of major procedure-related complications at 1-, 7-, and 30-days. To identify the factors influencing the operator's decision to discharge the patient on the same day, the secondary endpoint was to analyze clinical and procedural predictors of SDD. RESULTS: A total of 153 patients were discharged the same day after uncomplicated TLE (SDD), while 112 stayed at least overnight after the procedure (non-SDD). There was no significant difference in major procedure-related complications at 1-day (SDD 0% vs. non-SDD 1.8%, p value = ns), while patients in the SDD group had a lower rate of 7- and 30-day complications when compared with those in the non-SDD group (2.1% vs. 8.2%, p value = .0308; and 3.5% vs. 16%, p value = .0049, respectively). Noninfectious indication for TLE (OR 16.1, 95% confidence interval [CI] 4.29-77.6) and procedure end time before 12:00 (OR 2.82, 95% CI 1.11-7.27) were the only independent predictors of SDD. CONCLUSION: SDD discharge following uncomplicated TLE in selected patients (i.e., those without device infection and when the TLE procedure is completed in the morning) is feasible and safe.


Assuntos
Hospitalização , Alta do Paciente , Humanos , Remoção de Dispositivo , Estudos de Viabilidade , Estudos Retrospectivos , Resultado do Tratamento
10.
Artigo em Inglês | MEDLINE | ID: mdl-38069973

RESUMO

BACKGROUND: Studies have reported development of pulmonary hypertension (PH) secondary to reduced LA compliance following AF ablation. OBJECTIVES: We aimed to compare the risk of worsening of baseline PH between non-paroxysmal AF patients undergoing pulsed-field ablation (PFA) and standard radiofrequency ablation (RFA). METHODS: This multicenter study included 28 nonparoxysmal AF patients with PH undergoing a PFA-based ablation procedure after >1 failed RFA. A cohort of 28 AF patients with PH, scheduled for repeat RFA, 1:1 propensity-score matched using a multivariable logistic model, were used as the comparator group. Right heart catheterization and echocardiography were performed before and after the procedure to assess the pulmonary artery pressure (PAP). PH was defined as resting mean PAP of >20 mm Hg. RESULTS: The baseline characteristics of the PFA and propensity-matched RFA groups were comparable. The mean PAP assessments at baseline, follow-up, and change from baseline were analyzed. The groups had comparable baseline mean pulmonary artery pressures (mPAP) (P = 0.177). After adjustment for baseline mPAP in an analysis of covariance model, the least-squares means change at 3 months after ablation was -1.71 ± 1.03 mm Hg and 19.67 ± 1.03 mm Hg in PFA and RFA, respectively (P <0.001). CONCLUSIONS: In this propensity-matched population, no worsening of mPAP was detected following pulsed-field ablation in patients with pre-existing PH undergoing a repeat procedure for recurrence.

11.
J Cardiovasc Electrophysiol ; 34(12): 2527-2534, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37746923

RESUMO

INTRODUCTION: Earlier studies have shown a clear association between severity of human immunodeficiency virus (HIV) infection and incident atrial fibrillation (AF). We present the long-term outcome of catheter ablation (CA) and electrophysiological characteristics in HIV+ AF patients. METHODS: This study evaluated 1438 consecutive AF patients [31 (2.15%) with HIV and 1407 (97.8%) without HIV diagnosis] undergoing their first CA at our center. A total of 31 HIV patients and 31 controls were generated by propensity matching, based on calculated risk factor scores, using a logistic model. During first procedure, all received isolation of pulmonary vein (PV) + posterior wall and superior vena cava. Non-PV triggers, defined as ectopic triggers originating from sites other than PVs, were identified at the redo ablation with high-dose isoproterenol challenge. RESULTS: Clinical characteristics were not different between the groups. When compared to the control, by the end of 5 years after the first procedure, recurrence was significantly greater in HIV group [100% vs. 54%, p < .001]. Among patients that underwent redo ablation non-PV triggers were higher in HIV group [93.5% vs. 54%, p < .001], and most frequently originated from the coronary sinus [67.7% vs. 45.2%, p < .001] and left atrial appendage [41.9% vs. 25.8%, p < .001]. After focal ablation of non-PV trigger, no difference in arrhythmia recurrence between two groups [80.6% vs. 87.1%, p = .753] at 1-year follow up was found. CONCLUSION: Our findings suggest that non-PV triggers are highly prevalent in HIV+ AF patients resulting in higher rate of the mid- and long-term arrhythmia recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Infecções por HIV , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Infecções por HIV/complicações , Infecções por HIV/diagnóstico , Veia Cava Superior , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
13.
Curr Cardiol Rep ; 25(9): 1075-1082, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37505398

RESUMO

PURPOSE OF REVIEW: Atrial fibrillation (AF) is the most common sustained cardiac arrhythmia. The estimated lifetime risk of developing AF is higher in men; however, due to differences in life expectancy, the overall prevalence is higher among women, particularly in the older age group. Sex differences play an important role in the pathophysiology, presentation, and clinical outcomes of AF. Awareness of these differences minimizes the potential for disparities in AF management. Our review summarizes the current literature on sex differences in AF, including the epidemiology, pathophysiology, risk factors, clinical symptomatology, mechanisms, treatment, and outcomes. We also explore the implications of these differences for clinical practice and future research. RECENT FINDINGS: Women are more likely to present with atypical symptoms, have a higher stroke risk, and have a worse quality of life with AF when compared to men. Despite this, they are less likely to receive rhythm control strategies and anticoagulants. The sex-based differences in AF pathology and management might be a combination of inherent biological and hormonal differences, and implicit bias of the research entities and treating clinicians. Our review stresses the need for further sex-specific research in the pathophysiology of AF and opens a dialogue on personalized medicine, where management strategies can be tailored to individual patient characteristics, including sex.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Feminino , Humanos , Masculino , Idoso , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/terapia , Fibrilação Atrial/diagnóstico , Caracteres Sexuais , Qualidade de Vida , Fatores de Risco , Anticoagulantes/uso terapêutico , Fatores Sexuais , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
14.
J Cardiovasc Electrophysiol ; 34(8): 1690-1697, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37417961

RESUMO

INTRODUCTION: Transseptal puncture (TSP) to allow for large delivery sheath left atrial (LA) access remains a challenging aspect of LA appendage closure (LAAC) in patients with prior history of TSP, thick or lipomatous septum, atrial septal aneurysms, or other complex cardiac anatomies. This study investigates the use of the VersaCross large access (VLA) system (Baylis Medical/Boston Scientific) to improve procedural efficiency of LAAC compared to the standard needle workflow. METHODS AND RESULTS: Fifty LAAC procedures using WATCHMAN FLX between November 2021 and September 2022 were retrospectively analyzed comparing the VLA workflow (n = 25) to the standard needle workflow (n = 25). Study primary endpoint was time to procedural efficiency, and secondary endpoints included TSP time, acute LAAC success, fluoroscopy use, device recaptures, and periprocedural complications. Acute LAAC was successfully completed in all cases with no intraprocedural complications. TSP time was faster, but not significant, using the VLA workflow compared to the standard RF needle workflow (2.6 ± 1.1 min vs. 3.0 ± 1.8 min, p = 0.38). Time to WATCHMAN sheath in LA from TSP was 27% faster (1.5 ± 0.8 min vs. 2.1 ± 0.9 min; p = 0.03), and time to WATCHMAN release from TSP was 19% faster (10.5. ± 2.5 min vs. 13.0 ± 3.7 min; p = 0.01) with the VLA workflow. Overall procedure time was 15% faster (30.4 ± 5.1 min vs. 36.0 ± 6.6 min; p = 0.003) using VLA. Fluoroscopy time was 25% lower (4.0 ± 2.2 min vs. 5.5 ± 2.3 min; p = 0.003) and fluoroscopy dose was 60% lower (97.0 ± 91.7 mGy vs. 241.8 ± 240.6 mGy; p = 0.01) and more consistent [F-test, p ˂ 0.0001] using the VLA workflow compared to the needle workflow. CONCLUSION: The VLA system streamlines LAAC procedures, improving LAAC efficiency and reducing fluoroscopy use by allowing for de novo dilation of the septum for large-bore delivery sheaths, and reducing device exchanges and delivery sheath manipulation.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Cateterismo Cardíaco , Átrios do Coração , Resultado do Tratamento
15.
JACC Clin Electrophysiol ; 9(7 Pt 2): 1051-1059, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37086226

RESUMO

BACKGROUND: Acute pericarditis is a known complication of ablation procedures for atrial fibrillation (AF). OBJECTIVES: This study aimed to evaluate the benefits of colchicine monotherapy in terms of reducing the risk of pericarditis and related hospitalization rate in AF patients undergoing catheter ablation. METHODS: Consecutive AF patients undergoing first catheter ablation were classified into 3 groups based on their colchicine use: Group 1: no colchicine; group 2: colchicine from 7 days before to 1 month after ablation; and group 3: colchicine from the day of the procedure to 1 month after. Standard institutional protocol was used to follow all patients for 1 year. RESULTS: A total of 1,075 patients were classified into groups 1 (n = 607), 2 (n = 213), and 3 (n = 255). Symptoms of acute pericarditis were reported in 129 patients (12%): group 1: n = 106 (17.5%); group 2: n = 4 (1.9%); and group 3: n = 19 (7.5%); P < 0.001. Rate of mild-moderate as well as severe pericarditis were significantly lower in group 2. In the multivariable regression analysis, pre- and post-ablation colchicine use was seen to be associated with significantly lower risk of acute pericarditis and related hospitalization compared with the other 2 groups. In addition, at 1-year follow-up, arrhythmia-free survival rate was significantly higher in paroxysmal AF patients receiving colchicine compared with the no-colchicine population. CONCLUSIONS: Colchicine therapy starting 7 days before to 1 month after the ablation procedure was associated with significantly lower risk of acute pericarditis and related hospitalization. In addition, paroxysmal AF patients receiving colchicine had a higher arrhythmia-free survival rate compared with those not receiving colchicine.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Pericardite , Humanos , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Resultado do Tratamento , Colchicina/uso terapêutico , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Pericardite/epidemiologia , Pericardite/etiologia , Pericardite/cirurgia
16.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-36942834

RESUMO

AIMS: This study aimed to examine the clinical benefits of targeted ablation of all Premature ventricular complex (PVC) morphologies vs. predominant PVC only. METHODS AND RESULTS: A total of 171 consecutive patients with reduced left ventricular ejection fraction (LVEF) and ≥2 PVC morphology with high burden (>10%/day) undergoing their first ablation procedure were included in the analysis. At the initial procedure, prevalent PVC alone was ablated in the majority. However, at the redo, all PVC morphologies were targeted for ablation. : At the first procedure, 152 (89%) patients received ablation of the dominant PVC only. In the remaining 19 (11%) patients, all PVC morphologies were ablated. At two years, high PVC burden was detected in 89 (52%) patients. Repeat procedure was performed in 78 of 89, where all PVC morphologies were ablated. At 5 years after the repeat procedure, 71 (91%) had PVC burden of <5% [3.8 ± 1.1% vs. 15.4 ± 4.3% in successful vs. failed subjects (P < 0.001)]. In patients with low PVC burden after the initial procedure, LVEF improved from 37.5% to 41.6% [mean difference (MD): 3.39 ± 2.9%, P < 0.001], whereas a reduction in LVEF from 39.8% to 34.5% (MD: 6.45 ± 4.7%, P < 0.001) was recorded in patients with high PVC burden. One year after the repeat procedure, LVEF improved from 36.2% to 41.7% (MD: 5.5 ± 4.3%, P < 0.001) in patients with successful ablation. CONCLUSION: In this observational series, ablation of all PVC morphologies was associated with significantly lower PVC burden and improvement of LVEF at long-term follow-up, compared with ablation of the dominant morphology only.


Assuntos
Ablação por Cateter , Disfunção Ventricular Esquerda , Complexos Ventriculares Prematuros , Humanos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Complexos Ventriculares Prematuros/complicações
18.
J Cardiovasc Electrophysiol ; 34(1): 147-152, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36378783

RESUMO

INTRODUCTION: Atrial fibrillation (AF) and premature ventricular complexes (PVC) are common arrhythmias. We aimed to investigate AF prevalence in patients with PVC and its impact on PVC ablation outcomes. METHODS: Consecutive patients undergoing PVC ablation at a single institution between 2016 and 2019 were included and prospectively followed for 2 years. Patients with severe valvular heart disease, hyperthyroidism, malignancy, alcohol use disorder and advanced renal/hepatic diseases were excluded. Twelve-lead electrocardiograms were used to diagnose AF and assess PVC morphology. All PVCs were targeted for ablation using 4-mm irrigated-tip catheters at standardized radiofrequency power guided by 3-D mapping and intracardiac echocardiography. Patients were followed with remote monitoring, device interrogations and office visits every 6 months for 2 years. Detection of any PVCs in follow-up was considered as recurrence. RESULTS: A total of 394 patients underwent PVC ablation and 96 (24%) had concurrent AF. Patients with PVC and AF were significantly older (68.2 ± 10.8 vs. 58.3 ± 15.8 years, p < .001), had lower LV ejection fraction (43.3 ± 13.3% vs. 49.6 ± 12.4%, p < .001), higher CHA2 DS2 -VASc (2.8 ± 1.3 vs. 2.0 ± 1.3, p < .001) than those without. PVCs with ≥2 morphologies were detected in 60.4% and 13.7% patients with vs without AF (p < .001). At 2-year follow-up, PVC recurrence rate was significantly higher in patients with vs without AF (17.7% vs. 9.4%, p = .02). CONCLUSION: AF was documented in 1/4 of patients undergoing PVC ablation and was associated with lower procedural success at long-term follow-up. This was likely attributed to older age, worse LV function and higher prevalence of multiple PVC morphologies in patients with concurrent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Prevalência , Volume Sistólico , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/epidemiologia , Complexos Ventriculares Prematuros/cirurgia , Ablação por Cateter/efeitos adversos
19.
Am J Med ; 136(3): 225-233, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36495932

RESUMO

Racial and ethnic disparities in health care are well documented, although often underappreciated. In the setting of atrial fibrillation, stroke risk and severity may be higher in underrepresented ethnic populations. Additionally, the risk of bleeding is not uniform, and pharmacogenetics play an important role in anticoagulant therapy. In this narrative review, we discuss the complex issues surrounding stroke prevention in underrepresented ethnic groups with atrial fibrillation.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Grupos Raciais , Anticoagulantes/uso terapêutico , Hemorragia , Disparidades em Assistência à Saúde
20.
J Cardiovasc Electrophysiol ; 34(2): 348-355, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36448428

RESUMO

INTRODUCTION: Early and safe ambulation can facilitate same-day discharge (SDD) following catheter ablation, which can reduce resource utilization and healthcare costs and improve patient satisfaction. This study evaluated procedure success and safety of the VASCADE MVP venous vascular closure system in patients with atrial fibrillation (AF). METHODS: The AMBULATE SDD Registry is a two-stage series of postmarket studies in patients with paroxysmal or persistent AF undergoing catheter ablation followed by femoral venous access-site closure with VASCADE MVP. Efficacy endpoints included SDD success, defined as the proportion of patients discharged the same day who did not require next-day hospital intervention for procedure/access site-related complications, and access site sustained success within 15 days of the procedure. RESULTS: Overall, 354 patients were included in the pooled study population, 151 (42.7%) treated for paroxysmal AF and 203 (57.3%) for persistent AF. SDD was achieved in 323 patients (91.2%) and, of these, 320 (99.1%) did not require subsequent hospital intervention based on all study performance outcomes. Nearly all patients (350 of 354; 98.9%) achieved total study success, with no subsequent hospital intervention required. No major access-site complications were recorded. Patients who had SDD were more likely to report procedure satisfaction than patients who stayed overnight. CONCLUSION: In this study, 99.7% of patients achieving SDD required no additional hospital intervention for access site-related complications during follow-up. SDD appears feasible and safe for eligible patients after catheter ablation for paroxysmal or persistent AF in which the VASCADE MVP is used for venous access-site closure.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Alta do Paciente , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Satisfação do Paciente , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Sistema de Registros , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...